Zebra Technologies R110XiTM Printer User Manual


 
Front Panel Controls
Front Panel LCD
23063L-003 Rev. 2 12/23/04 R110Xi/R170Xi User Guide 57
APPLICATOR PORT
Setting the Applicator Port
Determines the action of the applicator port.
Note • Set this value as suggested by the applicator manufacturer.
Off: The applicator port is off.
Mode 1: Asserts the ~END_PRINT signal low while the printer is moving the
label forward.
Mode 2: Asserts the ~END_PRINT signal high while the printer is moving
the label forward.
Mode 3: Asserts the ~END_PRINT signal low for 20 milliseconds when a
label has been completed and positioned. Not asserted during continuous
printing modes.
Mode 4: Asserts the ~END_PRINT signal high for 20 milliseconds when a
label has been completed and positioned. Not asserted during continuous
printing modes.
Press the right or left oval to display other choices.
Default: OFF
Selections: OFF, MODE 1, MODE 2, MODE 3, MODE 4
START PRINT SIG
Start Print Signal
This parameter determines how the printer reacts to the Start Print Signal input on
pin 3 of the applicator interface connector at the rear of the printer.
•In Pulse Mode, labels print when the signal transitions from HIGH to LOW.
•In Level Mode, labels print as long as the signal is asserted LOW.
Caution • Start Print Signal is set by the applicator manufacturer and should not
be changed unless the factory defaults have been reloaded. The printer must be
returned to its designated setting for it to work properly.
•Press the right or left oval to display other choices.
Default: PULSE MODE
Selections: PULSE MODE, LEVEL MODE
Table 7 • Standard LCD Displays (Page 14 of 16)
Parameter Action/Explanation