Zebra Technologies XiIII Series Printer User Manual


 
58 Zebra XiIII-Series User’s Guide
Press Display Shows Action/Explanation
APPLICATOR PORT
Setting the Applicator Port: Press the RIGHT or LEFT
BLACK OVAL key to display other choices.
Default: Off
Selections: Off, mode 1, mode 2, mode 3, mode 4
Determines the action of the verifier port.
Off: The applicator port is off.
Mode 1: Asserts the ~END_PRINT signal low while the
printer is moving the label forward.
Mode 2: Asserts the ~END_PRINT signal high while the
printer is moving the label forward.
Mode 3: Asserts the ~END_PRINT signal low for 20
milliseconds when a label has been completed and
positioned. Not asserted during continuous printing modes.
Mode 4: Asserts the ~END_PRINT signal high for 20
milliseconds when a label has been completed and
positioned. Not asserted during continuous printing modes.
NOTE: Set as suggested by the applicator manufacturer.
WEB S.
These parameters are automatically set during the calibration
procedure. They should only be changed by a qualified service
technician. Refer to the maintenance manual for more
information on these parameters.
Press the NEXT/SAVE key repeatedly to skip these
parameters.
MEDIA S.
RIBBON S.
MARK S.
MARK MED S.
MEDIA LED
RIBBON LED
MARK LED