Zebra Technologies XiIII Series Printer User Manual


 
Zebra XiIII-Series User’s Guide 89
*HQHUDO6SHFLILFDWLRQV
General Specifications 90/96XiIII 140XiIII 170XiIII 220XiIII
Height 15.5" 393.7 mm 15.5" 393.7 mm 15.5" 393.7 mm 15.5" 393.7 mm
Width 9.15" 232.4 mm 11.15" 283.2 mm 13.15" 334.4 mm 15.65" 397.5 mm
Depth 19.5" 495.3 mm 19.5" 495.3 mm 19.5" 495.3 mm 19.5" 495.3 mm
Weight (without options) 50 lb 22.7 kg 55 lb 25 kg 67 lb 30.5 kg 72 lb 32.7 kg
Electrical
General (auto adjusting) 90-264 VAC;
48-62 Hz
90-264 VAC;
48-62 Hz
90-264 VAC; 48-
62 Hz
90-264 VAC;
48-62 Hz
Power
Consumption
Printing
PAUSE test
label at
slowest
speed
121 W 180 W 220 W 269 W
Printer idle 20 W 19 W 19 W 20 W
Compliance Complies with FCC class “B” and Canadian Doc. class “A” rules.
Carries the CE mark of compliance.
Temperature
Operating
environment
Thermal
transfer
41° to
104° F
5° to
40° C
41° to
104° F
5° to
40° C
41° to
104° F
5° to
40° C
41° to
104° F
5° to
40° C
Direct
thermal
32° to
104° F
0° to
40° C
32° to
104° F
0° to
40° C
32° to
104° F
0° to
40° C
32° to
104° F
0° to
40° C
Storage –40° to
140°F
–40° to
60° C
–40° to
140°F
–40° to
60° C
–40° to
140°F
–40° to
60° C
–40° to
140°F
–40° to
60° C
Relative Humidity Operating Environment 20% to 85% non-condensing
Storage 5% to 85% non-condensing