^RT – Read Tag
The format for the ^RT instruction is:
^RT#,b,n,f,r,m,s
where the parameters are:
# = number to be assigned to the field
Default value: 0
Other Values: 1 to 9999
b = starting block number
Default value: 0
Other values: 1 to n, where n is the maximum number of
blocks for the tag
n = number of blocks to read
Default value: 1
Other values: 2 to n, where n is maximum number of blocks
minus starting block number. In other words, if the tag has 8
blocks (starting with block 0) and you’re starting with block 6,
n can be 2. This would give you block 6 and block 7
information.
f = format
Default value: 0 ASCII
Other value: 1 Hexadecimal
r = retries
Default value: 0
Other values: 1 to 10, number of retries
m = motion
Default value: 0 (Feed label after writing)
Other value: 1 (No Feed after writing, other ZPL may cause
a feed)
s =
Default value: 0 (Least Significant Byte first)
Other value: 1 (Most Significant Byte first)
38 980476-001A