Getting Started
Using the Control Panel to View and Modify Print Server Parameters
04/19/2007 ZebraNet
®
10/100 Internal Print Server for ZM400 and ZM600 User Guide 14197L-001 Rev. A
Using the Control Panel to View and Modify Print
Server Parameters
You may change several print server parameters using the control panel on the printer. Table 4
shows the parameters that may be viewed or modified through the printer’s control panel for
printers with firmware version V53.15.x or later. (Printers with older versions of firmware
have a different set of parameters.)
Table 4 • Print Server Parameters
Parameter
Function
LIST NETWORK Print a Network Configuration Label
Use this parameter to print a network configuration label (see Figure 9
on page 35).
IP PROTOCOL
1
View the Method to Obtain an IP Address
This parameter tells if the user (permanent) or the server (dynamic) selects
the IP address. If a dynamic option is chosen, this parameter tells the
method(s) by which the print server (wired or wireless) receives the IP
address from the server.
Selections: ALL, BOOTP, DHCP, DHCP AND BOOTP, PERMANENT
Default Value: All
IP ADDRESS
1
View the Print Engine’s IP Address
Default Value: 0.0.0.0
SUBNET MASK
1
View the Subnet
Default Value: 255.255.255.0
DEFAULT GATEWAY
1
View the Gateway
Default Value: 0.0.0.0
RESET NETWORK
1
Reset the Wired or Wireless Network
Use this parameter to reinitialize the wireless radio card and the print server
(wired or wireless) when the wireless print server is running. This
parameter also causes any wireless radio card in the printer to reassociate to
the wireless network.
ACTIVE PRINTSRVR
View the Active Print Server
Selections: Wired, Wireless
Default Value: Wired
PRIMARY NETWORK
View the Primary Network
Default Value: Internal Wired
1 These parameters appear after the system recognizes the existence of a ZebraNet print server (wired or wireless). After the
print server is recognized, all zeroes (000.000.000.000) will display until the printer obtains an IP address or defaults to
address 192.168.254.254.