Zoom Series 1063 Modem User Manual


 
27
number you are calling.
If you still have a V.92 problem, you may want
to modify your Internet Connection string in
Windows: On your desktop, double-click the My
Computer icon, and then double-click Dial-up
Networking. Right-click the existing Internet
Connection that you wish to modify and select
Properties. Click General | Configure |
Connection | Advanced.
You can add initialization (init) strings on the
line labeled Extra Settings. Enter one of the init
strings listed below. Try these commands one
at a time until you find the one that gives you
the highest possible connection rate for your
telephone line conditions.
Init String Definition
ATW2S7=150+MS=V90
OR AT&F+MS=V92
S7 Sets wait time for remote
carrier, wait time can be 1-
255 seconds
AT&FS7=150 &F Sets factory defaults
AT&F&C1&D2\N5=1S7=100
&C1
DCD (Data Carrier Detect)
follows the remote carrier
signal
&D2 DTR (Data Terminal Ready)
reacts with a disconnect,
sends “OK” response and
disables auto-answer while
DTR signal is OFF
\N5 MNP Error Correction Only
\A2 Maximum block size: 192
characters