Status Registers & Result Codes 29
Register Dec. Function & Description Default
Don’t use
S36=1 or 3, and S48=7
LAPM or async
S36=1 or 3, and S48=128
Async
S36=4 or 6, and S48=7
LAPM, MNP or hang up
S36=4 or 6, and S48=128
MNP or hang up
S36=5 or 7, and S48=7
LAPM, MNP or async
S36=5 or 7, and S48=128
MNP or hang up
S89= 0, 5 - 60 Sleep mode control timer. Specify the number of seconds of
inactivity (no character sent from DTE, no RING) in the off-
line command state before the modem places itself into
standby mode. A value of “0” prevents standby mode.
If a number between 1 and 4 is entered for this register, it
will set the value to 5.
030
S91= 6 - 15 Transmitting power level adjustment (Japanese version only)
Range: -6 dBm to -15 dBm
Default: -15 dBm
014
Result Code Options
Result Code Options Table
ATV0 ATV1 X0 X1 X2 X3 X4 X7
0OK
999999
1 CONNECT
999999
2 RING
999999
3 NO CARRIER
999999
4 ERROR
999999
5 CONNECT 1200 EC* @ @ @ @
6 NO DIAL TONE
999
7BUSY
999
8 NO ANSWER
999999
10 CONNECT 2400 EC * @ @ @ @
11 CONNECT 4800 EC * @ @ @ @
12 CONNECT 9600 EC * @ @ @ @
13 CONNECT 14400 EC * # # # #
14 CONNECT 19200 EC * @ @ @ @
18 CONNECT 57600 EC * % % % %
24 CONNECT 7200 EC * # # # #
25 CONNECT 12000 EC * # # # #
28 CONNECT 38400 EC * % % % %
40 CONNECT 300 EC * @ @ @ @
55 CONNECT 21600 EC * # # # #
56 CONNECT 24000 EC * # # # #
57 CONNECT 26400 EC * # # # #
58 CONNECT 28800 EC * # # # #