ZyXEL Communications 56K II, 56K Plus II Network Card User Manual


 
Omni 56K II and Omni 56K Plus II User’s Guide
Command Sets 5-13
5.2.2 Service Class 2 Commands
The following Class 2 commands are supported and implemented as per TIA PN2388 (8/20/90):
Table 5-8 Service Class 2 Command Syntax
COMMAND SYNTAX DESCRIPTION
+<command>=<value> Execute a command or set a parameter.
+<command>=? Read permissible settings.
+<command>? Read current setting.
Table 5-9 Service Class 2 Commands Supported Commands (per TIA PN2388 8/20/90)
COMMAND DESCRIPTION VALUE
+FAA=n Automatic answer mode parameters.
Answer as set by +FCLASS. n=0
DCE answers and automatically determines the type of call. n=1
+FBADLIN=
<value>
Bad line threshold (number of consecutive bad lines for a bad page
parameter).
Determine if Copy Quality is OK on the T.30 flow chart. A value of 0
implies that error checking is disabled.
0-255
+FBOR=n Phase C data bit order:
Select direct bit order. n=0
Select reversed bit order in receiving mode for phase C data. n=1
+FBUF? Buffer size. This Read Only parameter allows the DTE to determine the
characteristics of the DCE’s buffer size.
+FCIG="string" Sets the local fax station ID string that is sent to polling Rx.
+FCLASS=n Service class selection. Refer to the +FCLASS Service Class 1 command
in Table 5-6.
+FCON DCE automatically responds to a fax connection.
+FCQ=n Sets the copy quality check capability parameters.
Disables the copy quality check capability. n=0