Synchronizing the transmitter with an EK 300 IEM G3 receiver
34
Operation without network
̈ Carry out the Easy Setup Sync function and then, for each transmitter/receiver pair, the
Sync function (
see page 17).
This establishes a transmission link between the transmitter and the receiver.
Using freely selectable transmission frequencies
You can also freely select the frequencies and store these frequencies in the frequency banks
“U1” to “U6”.
If you want to use the frequency banks “U1” to “U6”:
̈ Make sure to use transmitters and receivers from the same frequency range (see page 4
and the type plates of the devices).
̈ Only use frequencies that are approved and legal in your country (see page 33).
̈ Set each transmitter to the same frequency bank.
̈ On one of the transmitters, select a channel within this frequency bank (see page 20).
̈ Assign this channel one of the calculated transmission frequencies (see page 20).
̈ Synchronize a receiver with your transmitter ( ,
see page 17
).
OR
̈ Manually set the receiver to the same frequency bank, channel and frequency that you set
on the transmitter.
̈ Repeat for the remaining transmitters and receivers as described above.
To ensure that the desired frequencies are intermodulation-free:
̈ Contact your Sennheiser partner (see www.sennheiser.com).