A SERVICE OF

logo

G7 ASD Operation Manual 179
Overheat Cooling fan inoperative.
Ventilation openings are obstructed.
Internal thermistor is disconnected.
Over Speed Result of a motor speed that is greater than the commanded speed when using an
encoder for speed control.
Improper encoder connection or setup information.
Defective encoder.
Overtorque A torque requirement by the load in excess of the setting of F616 or F617 for a
time longer than the setting of F618.
The ASD is improperly matched to the application.
The load is obstructed.
Overvoltage During Acceleration Motor running during restart.
Note: The event that caused the Trip(s) must be corrected or must decrease to less than the threshold
value required to cause the trip to allow for a Reset to be recognized. In the event of multiple
active trips, the trip displayed will remain until all faults are corrected and all trips are cleared.
Overvoltage During Deceleration Deceleration time is too short.
DBR value is too high.
DBR required (DBR setup required).
Stall protection is disabled.
3-phase input voltage is out of specification.
Input reactance required.
Overvoltage During Run Load fluctuations.
3-Phase input voltage out of specification.
PG Type/Connection Error ASD is configured to receive a signal from a shaft-mounted encoder and no signal
is being received while running.
Disconnection at the Encoder circuit.
Motor is stopped and is generating torque via torque limit control.
ASD is not configured properly.
Phantom Fault In a multiple ASD configuration a faulted ASD signals the remaining ASDs that a
fault has occurred and shuts down the non-faulted ASDs.
Position Deviation Error Operating in the Position Control mode and the resulting position exceeds the
limits of the F631 setting.
RAM Fault Internal RAM malfunction.
ROM Fault Internal ROM malfunction.
Sink/Source Setting Error Improperly positioned Sink/Source jumper on the control board or on an option
device.
Sink/Source configuration of an option device is incorrect.
Torque Proving Fault Lift-First Pulse Count (F743) adjustment required.