G7 ASD Operation Manual 93
VI/II Speed Reference Setpoint #2 (%)
Program Frequency Setting Parameters Speed Reference
Setpoints VI/II
This parameter is used to set the gain and bias of the VI/II input terminals when
either terminal is used as the control input while operating in the Speed
Control or the Torque Control mode.
See F201 for further information on this setting.
This parameter sets the VI/II input level that represents Reference Setpoint #2
(torque or frequency). This value is entered as 0 – 100% of the VI/II input
signal range.
Direct Access Number — F203
Parameter Type — Numerical
Factory Default — 100.0
Changeable During Run — Ye s
Minimum — 0.0
Maximum — 100.0
Units — %
VI/II Speed Reference Setpoint #2 (frequency)
Program Frequency Setting Parameters Speed Reference
Setpoints VI/II
This parameter is used to set the gain and bias of the VI/II input terminals when
either terminal is used as the control input while operating in the Speed
Control mode.
See F201 for further information on this setting.
This parameter sets VI/II Speed Reference Setpoint #2 (frequency) and is the
frequency that is associated with the setting of
F203.
Direct Access Number — F204
Parameter Type — Numerical
Factory Default — 80.0
Changeable During Run — Ye s
Minimum — 0.0
Maximum — Max. Freq. (F011)
Units — Hz
VI/II Torque Reference Setpoint #1 (%)
Program Torque Setting Parameters Setpoints VI/II
This parameter is used to set the gain and bias of the VI/II input terminals when
either terminal is used as the control input while operating in the Torque
Control mode.
This is accomplished by establishing an associated V/f output pattern for a
given VI/II input level and motor load.
See F201 for further information on this setting.
This parameter sets Torque Reference Setpoint #1 (%) and is the output
torque value that is associated with the setting of
F201. This value is entered as
0 to 250% of the rated torque.
Direct Access Number — F205
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Ye s
Minimum — 0.0
Maximum — 250.0
Units — %
VI/II Torque Reference Setpoint #2 (%)
Program Torque Setting Parameters Setpoints VI/II
This parameter is used to set the gain and bias of the VI/II input terminals when
either terminal is used as the control input while operating in the Torque
Control mode.
This is accomplished by establishing an associated V/f output pattern for a
given VI/II input level and motor load.
See F201 for further information on this setting.
This parameter sets Torque Reference Setpoint #2 (%) and is the output
torque value that is associated with the setting of
F203. This value is entered as
0 to 250% of the rated torque.
Direct Access Number — F206
Parameter Type — Numerical
Factory Default — 100.0
Changeable During Run — Ye s
Minimum — 0.0
Maximum — 250.0
Units — %
F203 F206