3Com 3500 Network Router User Manual


 
2 Quick Installation Guide
Installing the
System
To install the system in your network, follow the steps in this section.
WARNING: For safety reasons and to ensure adequate cooling airflow,
install blank faceplates over all empty slots.
Install the system in an area that meets the requirements in Table 1.
For more information, see Appendix A “System Specifications” and
Appendix C “Site Requirements and Safety Codes”
in the
Getting Started
Guide
.
Check the packing slip to verify that you have all components.
The system is shipped with one system processor module and one power
supply installed. If you have ordered a second power supply for the
system, be sure that it is available for installation.
Determine Site
Requirements
1
Table 1
System Site Requirements
Location
Ambient (room) temperature — 0 to 50 °C (32 to 122 °F) at sea level
Operating humidity — 10% to 90% relative humidity, noncondensing
Storage humidity — 10% to 95% relative humidity, noncondensing
A level surface for system installation
Power
Heat dissipation — 362 Watts
Power source location — Power source within approximately 1.8 meters
(6 feet)
Input voltage options — 90 VAC to 264 VAC
Current rating — 100 VAC at 3.8 amperes (maximum); 240 VAC at
1.5 amperes (maximum)
Unpack the
System
2