V6000 Analog Integrated Branch Office Solution Installation Guide V6000 Analog Integrated Branch Office Sol
18
2 Use a standard Telnet application to connect to the V6000 Embedded Telnet Server.
3 Login using the username (‘Admin’) and password (‘Admin’).
To access the CLI via the RS-232 port, follow these 2 steps:
1 Connect the V6000 RS-232 port (labeled I0I0), located on the CPU module of the V6000
front panel, to either COM1 or COM2 RS-232 communication port on your PC with the
supplied RS-232 cable.
2 Use serial communication software (e.g., HyperTerminal
TM
) to connect to the
V6000.
Set your serial communication software to the following communications port settings:
Baud Rate: 115,200 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow control: Hardware
The CLI prompt is available immediately.
Assigning an IP Address
To assign an IP address via the CLI, follow these 4 steps:
1 At the prompt type ‘conf’ and press enter; the configuration folder is accessed.
2 To check the current network parameters, at the prompt, type ‘GCP IP’ and press enter;
the current network settings are displayed.
3 Change the network settings by typing: ‘SCP IP [ip_address] [subnet_mask]
[default_gateway]’ (e.g., ‘SCP IP 10.13.77.7 255.255.0.0 10.13.0.1’); the new settings
take effect on-the-fly. Connectivity is active at the new IP address.
This command requires you to enter all three network parameters (each
separated by a space).
4 To save the configuration, at the prompt, type ‘SAR’ and press enter; the V6000 restarts
with the new network settings.