Restoring Networking Parameters to the Initial State
You can use the ‘Reset’ button to restore the V6000 networking parameters to their factory
default values (described in
Table 2) and to reset the username and password.
The V6000 returns to the software version burned in flash. This process also
restores the V6000 parameters to their factory settings. Therefore, you must load
your previously backed-up ini file, or the default ini file (received with the software
kit) to set them to their correct values.
To restore networking parameters to their initial state, follow these 3 steps:
1 Press in the ‘Reset’ button uninterruptedly for a duration of more than six seconds; the
gateway is restored to its factory settings (username: ‘Admin’, password: ‘Admin’).
2 Assign the V6000 IP address (see
Chapter 5: Assigning the V6000 IP Address).
3 Load your previously backed-up ini file, or the default ini file (received with the software
kit). For information on loading the ini file, refer to the V6000 User Manual.