3Com V7350 Network Card User Manual


 
Using the Web Interface 33
6 Enter values in the Sender, Recipient, Media, and Subject fields as
required. The entered values are applied according to the selected
Operator to restrict message notification according to the specified
values. The Operator options function as follows:
Field is empty (null value) and corresponding Operator is ALL — No
filtration. For example, if the Sender field is empty and Sender
Operator is ALL, messages from any sender result in user notification.
Field has a value and corresponding Operator is == — Messages
must include the specified field value for user notification to occur. For
example, if the Subject field value is “Status report” and the Subject
Operator is ==, only messages that include the string “Status report”
in the subject line result in user notification.
Field has a value and corresponding Operator is <> — Messages with
the specified field value are ignored. For example, if the Media field
value is Fax and the Media Operator is <>, all message types except
faxes result in user notification.
7 Click Save.
Create a Notification Procedure
To create a Notification procedure:
1 From the Main menu, click Notification Procedures.
The Notification Procedure screen appears.
Figure 9 Notification Procedures Screen
2 Click Add New.
Click Edit to edit an existing procedure or click Delete to delete an
existing procedure.
The Add Notification Procedure screen appears.