Accton Technology ETHERHUB-16SE Switch User Manual


 
SuperSmart User’s Guide
Setup and Configuration 4-5
Selections Available
This section shows the selections available for each function
and the corresponding LED display. The functions are listed
here in sequence.
Segment Setting
Active LEDs: Segment LEDs
Attach the hub to one segment.
Segment LED 1
Segment LED 2
Segment LED 3
Segment Number Selection
Blinking
OFF
OFF
Attach hub to Segment 1 (DEFAULT)
OFF
Blinking
OFF
Attach hub to Segment 2
OFF
OFF
Blinking
Attach hub to Segment 3
Demo function
Active LEDs: Partition LED 1
Link/Traffic LED 1 (labeled Demo)
Enabling the Demo function will light up all LEDs one at a time.
The LED display will continue until the Demo function is
disabled using the Configure button (Partition LED is OFF).
LED Activity Selection
Link/Traffic LED 1
BLINKING
Enable Demo function
Partition LED 1
BLINKING
Disable Demo function
Diagnostic function
Active LEDs: Partition LED 2
Link/Traffic LED 2 (labeled Diag)
Enabling the Diagnostic function will activate diagnostic tests
similar to the one performed upon power on. For diagnostic test
details, refer to the section on
Diagnostic Tests earlier in this chapter.
After succesfully completing Diagnostics, the system returns to
normal operation.
LED Activity Selection
Link/Traffic LED 2
BLINKING
Enable Diagnostic function
Partition LED 2
BLINKING
Stop Diagnostic function