Acer RA19WAANU Computer Monitor User Manual


 
S4
S5
S3
S2
S1
Use a Phillips-head screwdriver screwed the
No.1~2 screws till that interface board and bracket
chassis base firmly attached.
(No1~2 screw size=M3x6; Torque=9~10KGFxCM).
Use a Phillips-head screwdriver screwed the
No.1~4 screws till that power board and bracket
chassis base firmly attached.(No1~3 screw
size=M3x6; No4 screw size=M4x8;
Torque=9~10KGFxCM).
Connect the cable between power board(P802)
and interface board (P301)
Connect the function key cable into interface
board(P304)
Connect the FFC cable into interface board
4.1 Assembly procedures:
4. Assembly and Disassembly Procedures
Plug in parallel direction
P301
P802
P304
Take the key function cable out from the hole
shown as photo
Fix the function key cable with a PVC tape
1
2
3
4
1
2
Turn the monitor faced down and put it on the
bracket chassis module till both parts firmly
Connect FFC cable to LCD panel. There are
two locks over here when plugging in should
be noticed
Angel < 5 degrees
12
Go to cover page
FFC
ACER X193HQ