Acer RA19WAANU Computer Monitor User Manual


 
1.3.5 Controller Requirements
1.3.5.1 General Requirements
The monitor shall include a controller capable of
converting the analog RGB signal from a standard
SXGA resolution video controller in the CPU to a
signal which can be displayed on the panel. The
controller will include a PLL, A/D converters, LVDS
transmitter and other circuitry necessary to perform
its function. The PLL shall be stable enough to
ensure that a static image from the CPU is placed
in the same physical location on the flat panel in
each frame.
1.3.4.3 Mode Recognition Pull-in
The monitor shall recognize preset modes within a
range of +/-1KHz whichever is less for horizontal ;
and within +/-1Hz for vertical.
1.3.4.4 User Display Modes
In addition to the factory pre-set video modes,
provisions shall be made to store up to 9 user
modes. If the current mode is a user mode, the
monitor shall select its previously stored settings.
If the user alters a setting, the new setting will be
stored in the same user mode. The user modes
are not affected by the pre-set command. If the
input signal requires a new user mode, storage of
the new format is automatically performed during
user adjustment of the display (if required).(
Please see Note.(4) )
Preset timing Chart
1.3.5.2 Video Stretching
The monitor shall contain provisions to “stretch” the
video signal, so that an input signal from the
computer in any resolution smaller than 1366 x
768 is automatically expanded to fill the entire
screen.
1.3.5.3 Panel Timing and Interface
The controller supplied with the monitor shall
control all panel timing. This controller shall
adequately insulate the monitor from the computer,
so that no possible combination of input signals
from the computer shall cause damage to the flat
panel or any other component of the monitor. The
LCD panel interface shall support the TFT
standard.
1.3.6 DC - AC Inverter Requirements
The DC-AC inverter is on the power board. The
frequencies used by the DC-AC inverter used to power the
backlight shall be chosen so as to prevent any noticeable
effects on the flat panel (such as a rolling effect).
1.3.7 Power Supply Requirements
The AC to DC converter power supply for the monitor shall
be an external AC to DC converter ”brick” This brick shall
have an IEC receptacle for main power input and a pin - in
---socket for DC power out. The brick shall provide
sufficient power for both the monitor and the backlight
assembly, and shall meet requirements specified in Table
2.
1. Product Specification (continued)
Table 2. AC TO DC Converter Requirements
HV
1 T103 640x480@60Hz 31.469 59.941 25.175 - - VESA
2 T173 640x480@72Hz 37.861 72.809 31.500 - - VESA
3 T109 640x480@75Hz 37.500 75.000 31.500 - - VESA
4 T182 640x480@66.66Hz 35 66.66 30.24 - - MAC
5 T102 720x400@70Hz 31.469 70.087 28.322 - + VGA
6 T104 800x600@56Hz 35.156 56.250 36.000 + + VESA
7 T116 800x600@60Hz 37.879 60.317 40.000 + + VESA
8 T117 800x600@72Hz 48.077 72.188 50.000 + + VESA
9 T110 800x600@75Hz 46.875 75.000 49.500 + + VESA
10 T108 832x624@74.55Hz 49.722 74.55 57.28 - - VESA
11 T118 1024x768@60Hz 48.363 60.004 65.000 - - VESA
12 T157 1024x768@70Hz 56.476 70.069 75.000 - - VESA
13 T141 1024x768@75Hz 60.023 75.029 78.750 + + VESA
14 T203 1152x870@75Hz 68.700 75.000 84.520 - -
15 T126 1152x864@75Hz 67.5 75 108 + +
16 T161 1280x960@60Hz 60 60 108 + + VESA
17 T179 1280x1024@60Hz 63.981 60.020 108.000 + + VESA
18 T131 1280x1024@75Hz 79.976 75.025 135.000 + + VESA
19 T339
1280x720@60Hz 44.955 59.940 74.176
++
20 T213
1280x800@60Hz 49.702 59.810 83.500
++
21 T278
1366x768@60Hz 47.712 59.790 85.500
--
Preset Timing Chart
V-Sync
(KHz)
Band Width
(MHz)
Polarit
SourceItem No Resoulution
H-Sync
(KHz)
Input Voltage Range
The operating range shall be from 90 to 132 and 195 to 265 AVC
sinusoidal for all models specified.
Input Frequency Range
Input power frequency range sha;; be from 47.5to63Hzoverthe
specified input voltage range.
Power Consumption
Power consumption for the monitor shall be less than30W over the
specified voltage and frequency ranges. In suspend or sleep mode
the power consumption will be less than 2W.
Line Fuse
TheAC input shall be fused and become electrically open as a result
on an unsafe current level. The fuse many not be user replaceable.
Initial Cold Start
The power supply shall start and function properly when under full
load, with worst case conditions of input voltage, input frequenct,
operating temperature, and cold backlight lamps.
Inrush Current
The inrush current must be limited to 30Awhen operated at
120VAC, and 50Awhen operated at 220VAC. Inrush current is
measured at an ambient temperature of 25
o
C, with the unit
temperature stabilized in the power-off.
Hot Start Cycle
The power supply shall be damaged when switched ON for one
second and OFF for one second for seven consecutive after
operating for one hour at full load, 25
o
C, and nominal input line
voltage.
Under Voltage
The power supply shall contain protection circuitry such that the
application of an input voltage below the minimum specified in this
table shall not cause damage to the power supply unit nor cause
failure of the input.
Line Transient
The power supply shalloperate within IEC 801-4 (± 1KV) and IEC
801-5 (± 2KV) for the domestic U.S. version. The UPS power
supply shall operate and comply with CE mark.
ACtoDCConverterRequirements
Table 2
Go to cover page
5