Acnodes PCH 5120 Personal Computer User Manual


 
14628 Central Blvd,
Chino, CA91710
tel:909.597.7588, fax:909.597.1939
© Copyright 2011 Acnodes, Inc.
All rights reserved. Product description and product specifications
are subject to change without notice. For latest product information,
please visit Acnodes’ web site at www.acnodes.com.
PCH 5120
12.1” industrial Panel PC
IP67 rated fully enclosure
ƒ Serial Port Number [COM1]
Use the Serial Port Number option allows to select the serial port used for remote ac-
cess.
COM1DEFAULT System is remotely accessed through COM1
COM2 System is remotely accessed through COM2
NOTE: Make sure the selected COM port is enabled through the Super I/O configura-
tion menu.
ƒ Base Address, IRQ [2F8h,3]
The Base Address, IRQ option cannot be configured and only shows the interrupt ad-
dress of the serial port listed above.
ƒ Serial Port Mode [115200 8,n,1]
Use the Serial Port Mode option to select baud rate through which the console redirec-
tion is made. The following configuration options are available
ƒ 115200 8,n,1 DEFAULT
ƒ 57600 8,n,1
ƒ 38400 8,n,1
ƒ 19200 8,n,1
ƒ 09600 8,n,1
NOTE:
Identical baud rate setting musts be set on the host (a management computer running a
terminal software) and the slave
ƒ Flow Control [None]
Use the Flow Control option to report the flow control method for the console redirec-
tion application.
None DEFAULT No control flow,
Hardware Hardware is set as the console redirection
Software Software is set as the console redirection