Installation and operation
LOCAL module switches (continued)
LOCAL Switch 1
OFF: Normal operation.
ON: (Before power is applied) Places the LOCAL module into ash upgrade
mode so that the internal software can be changed. Please see the ‘Flash
upgrade’ section in the ‘Special conguration’ section.
ON: (Whilst power is applied) Places the REMOTE module into password
override mode. This allows any pre-congured passwords to be altered
- particularly useful when they have been lost or forgotten. Please see the
‘Password override’ section in the ‘Special conguration’ chapter.
LOCAL Switch 2
OFF: Normal operation.
ON: Set transparent mode. Use this setting if the X2 Multi Screen modules
are to be used with KVM switches that are not manufactured by Adder
Technology. Cascaded KVM switches often use special signals to set or
identify conditions. In transparent mode, the X2 Multi Screen modules will
pass the signals without attempting to interpret them.
LOCAL Switch 3
OFF: Microphone input on REMOTE module. Use this setting if a standard mono-
channel microphone is connected to the MIC input on the REMOTE unit.
ON: Stereo line-in input on REMOTE module. Use this setting if a stereo input is
applied to the MIC input on the REMOTE unit.
LOCAL Switch 4
OFF: Normal operation.
ON: Suspend operation and reset the LOCAL module. Use this setting
momentarily to produce the same effect as removing and restoring power
if incorrect operation has occurred. Return the switch to the OFF position
to allow normal operation to continue.
Installation
The installation of the X2 Multi Screen extenders is straightforward and can best
be achieved in most cases by following these stages for each module:
Stage A Check or set the conguration switch settings
Stage B Mount the module
Stage C Connect the cables
Stage A - Conguration switch settings
The basic operation of the LOCAL and REMOTE modules are controlled by the
banks of four switches located on the side of each module. The switches are
monitored at all times and may be changed when power is on or off (the only
exception to this rule is switch 1 of the LOCAL module which initiates slightly
different functions depending on the power state when it is switched).
LOCAL module switches
OFF: Normal operation
ON: Transparent mode
OFF: Normal operation
ON: Flash upgrade/reset
password modes
OFF: Normal operation
ON: Reset LOCAL module
OFF: Microphone input mode
ON: Stereo line-in mode
Note: When shipped, all switches are set in the OFF positions and this will
produce normal operation with normal microphone input (at the REMOTE
module).
1
O
N
2
3
4
1
ON
4
2
3
ON