6-14 Configuration
62-9301-01
When configuring Indexed addressing, the user is presented
a table with the current mappings. The user can then select a
table entry by FCP LUN and specify the associated
BUS:TARGET:LUN. Alternately, the user can fill with one of
multiple preset patterns, or with the list of currently attached
SCSI devices. The user then saves these values in FLASH
memory, where they are retained across future device resets
or power cycles.
Changing the Fibre Channel-to-SCSI
Mapping Mode
This option allows the user to select the appropriate Fibre
Channel-to-SCSI mapping mode on the FCR200. The options
are SCC addressing, Indexed addressing, and Auto
addressing. Auto addressing allows you to assign one of three
mapping priorities:
LUN priority
fills the table according to ascending
LUN order.
Target ID priority
Fills the table according to ascending
SCSI Target ID (SCSI device address
ID) order.
Bus Number priority
Fills the table in ascending SCSI Bus
Number (SCSI port ID number)
order.
Fibre Channel to SCSI Mapping Mode Configuration Menu
Version: X.X.XXXX
Current Fibre Channel to SCSI Mapping Mode is Auto-assigned
Bus Number Priority
1) Set to SCC
2) Set to Indexed
3) Set to Auto-assigned, LUN Priority
4) Set to Auto-assigned, Target ID Priority
5) Set to Auto-assigned, Bus Number Priority
X) Return to previous menu