ADTRAN E220 HFAC HDSL2 Network Card User Manual


 
10
61221051L1-5, Issue 1 61221051L1-5A
Shelf Status Summary Screen
The Shelf Status Summary Screen shown in Figure 9
provides a top-level look at the alarm and
provisioning of data for the shelf and each circuit
within the shelf.
HDSL / HDSL2 Status Screen
From the Shelf Status Summary Screen, detailed
information related to a particular circuit may be
accessed. The HDSL / HDSL2 Shelf Status Summary
screen related to a particular slot may be displayed by
typing the desired slot number and S. For example, to
access Slot 6 information, type 6S. The HDSL /
HDSL2 Status Summary Screen is shown in Figure
10. This screen gives both local and remote
performance and provisioning information for the
selected slot. If a supported HRE is present in the
HDSL / HDSL2 circuit, screen 10A is available to
view the performance of the HRE.
08/08/70 17:59:19 SHELF ADDRESS = 00
SHELF STATUS SUMMARY [ BYPASS = OFF ]
ACTIVE SHELF ALARMS HFAC ALARM THRESHOLD OPTION SETTINGS
————————— ——————————————————————————————————————————————————————
CRITICAL - YES ES SES UAS
MAJOR - NO SLOT TYPE THRSHLD TYPE THRSHLD TYPE THRSHLD
MINOR - NO ---- ------------- ------------- -------------
1: --- --- --- --- --- ---
FUSE ALARM SETTINGS 2: --- --- --- --- --- ---
—————————————————— 3: --- --- --- --- --- ---
HFAC : CRIT 4: --- --- --- --- --- ---
HTU-C : 1-5 = MAJ, 5: --- --- --- --- --- ---
6-13 = CRIT 6: --- --- --- --- --- ---
7:* MAJ 150 MAJ 075 CRIT 075
8: --- --- --- --- --- ---
LEGEND 9: --- --- --- --- --- ---
—————————————————— 10: --- --- --- --- --- ---
NA = NOT ALARMED 11: --- --- --- --- --- ---
* = DEFAULT 12:* MAJ 150 MAJ 075 CRIT 075
— = EMPTY SLOT 13:* MAJ 150 MAJ 075 CRIT 075
PRESS : “O” - change options, “D” - read HFAC switch defaults (all slots),
nn”S” - slot select (HDSL STATUS), “M” - main menu :
Figure 9. Shelf Status Summary Screen
Figure 10. Status Summary Screen
08/08/70 18:00:37 SUMMARY - [ SLOT 7 ] SHELF ADDRESS = 00
LOOP #1 <NETWORK> LOOP #2 ELAPSED TIME 00:09:56 LOOP #1 <CUSTOMER>LOOP #2
--------- HTU-C --------- --------- HTU-R ---------
01 dB 01 dB <- LOSS -> 01 dB 01 dB
YES YES <- SYNC -> YES YES
000/00001 000/00001 <- ES 15M/24H -> 000/00001 000/00001
000/00000 000/00000 <- SES 15M/24H -> 000/00000 000/00001
000/00026 000/00025 <- UAS 15M/24H -> 000/00026 000/00025
LOOPBACKS INACTIVE LOOPBACKS INACTIVE
HTU-C SIGNAL QUALITY DSX-1 DS1 HTU-R SIGNAL QUALITY
[X] 9 [X] ——————————————— [X] 9 [X]
L[X] 8 L[X] SF <- FRAME -> SF L[X] 8 L[X]
O[X] 7 O[X] AMI <- CODE -> AMI O[X] 7 O[X]
O[X] 6 O[X] EXT <- LBO -> 0 dB O[X] 6 O[X]
P[X] 5 P[X] N/A <- NIU -> NO P[X] 5 P[X]
[X] 4 [X] 00000 <- BPV -> 00000 [X] 4 [X]
1[X] 3 2[X] 00000 <- ES -> 00000 1[X] 3 2[X]
[X] 2 [X] 00000 <- SES -> 00000 [X] 2 [X]
[X] 1 [X] 00324 <- UAS -> 00302 [X] 1 [X]
[X] 0 [X] RED <- ALARMS -> RED [X] 0 [X]
SEALING CURRENT PRESENT
“P” - prev scrn,