ADTRAN E220 HFAC HDSL2 Network Card User Manual


 
12
61221051L1-5, Issue 1 61221051L1-5A
Shelf Controller Options
From the Shelf Status Summary Screen, all shelf
controller options may be reviewed. By typing O at
the Shelf Status Summary Screen, the Shelf Options
Setup Screen may be accessed. This screen is
illustrated in Figure 11.
External DSX-1 or DS1 threshold alarms (ES, SES,
UAS) can be enabled and disabled for a specific slot
by selecting the desired setting from the menu. If
disabled, these alarms will be suppressed, regardless
of how the HTU-C and HTU-R units are provisioned.
Performance Data Screen
From the Main Menu, a screen summarizing the 8-
hour performance data for all slots may be selected.
From the Main Menu, item 2 presents the
Performance Data Screen shown in Figure 12. This
screen graphically summarizes the performance
information for each slot. A key for understanding
the display is also presented.
Figure 11. Shelf Options Setup Screen
OPTIONS SETUP [SLOT = 8 ]
OPTION # OPTION SETTING
------------------------------------------------------
---> 1: HTU-C FUSE ALARM TYPE ---> 1-5 = MAJ, 6-13 = CRIT
SHELF | 2: SHELF ADDRESS ---> 00
OPTIONS | 3: SHELF BYPASS ---> OFF
---> 4: SET DATE/TIME ---> 11/22/99 09:30:31
---> 5: EXT HTU-C/HTU-R ALARMS ---> DISABLED
| 6: ES ALARM TYPE ---> MAJOR
SLOT | 7: SES ALARM TYPE ---> MAJOR
OPTIONS | 8: UAS ALARM TYPE ---> CRITICAL
| 9: ES ALARM THRESHOLD ---> 150
| 10: SES ALARM THRESHOLD ---> 075
---> 11: UAS ALARM THRESHOLD ---> 075
PRESS: “P” - previous screen
nn”X” - change option n (ex. 4X)
nn”S” - select slot (ex. 11S)
“D” - read HFAC switch defaults(this slot only)
“M” - main menu
-> <-
Figure 12. Performance Data Screen
11/23/99 00:15:21 [ SLOT = 8 ] SHELF ADDRESS = 00
PERFORMANCE DATA <VIEW 1 - HTU-C DSX-1 RECEIVER>
24 HOUR REGISTERS 15 MINUTE REGISTERS
-------ES------SES- ------ES----SES------------ES----SES
00000 00000 <---- CURRENT ----> 000 000
-1 : 00000 00000 <-- --> -1 : 000 000 -17 : --- ---
-2 : ----- ----- | | -2 : 000 000 -18 : --- ---
-3 : ----- ----- | | -3 : 000 000 -19 : --- ---
-4 : ----- ----- |--PREVIOUS -- | -4 : --- --- -20 : --- ---
-5 : ----- ----- | | -5 : --- --- -21 : --- ---
-6 : ----- ----- | | -6 : --- --- -22 : --- ---
-7 : ----- ----- <— | -7 : --- --- -23 : --- ---
| -8 : --- --- -24 : --- ---
| -9 : --- --- -25 : --- ---
VIEW LOCATION DIAGRAM | -10 : --- --- -26 : --- ---
| -11 : --- --- -27 : --- ---
1-->|H|-3---|H|-----|H|---4-|H|-> | -12 : --- --- -28 : --- ---
|T| |R| |R| |T| | -13 : --- ---— 29 : --- ---
|U| |E| |E| |U| | -14 : --- --- -30 : --- ---
<-- |C|-5---|1|-----|2|---6-|R|<-2 | -15 : --- --- -31 : --- ---
--> -16 : --- --- -32 : --- ---
PRESS : n”V” - view (ex. 4V), “nH” - element (0H=HTU-C/R, 1H=HRE1, 2H=HRE2),
nn”S” - slot (ex. 3S), “M” - main menu, “P” - prev. screen :