ADTRAN E220 HFAC HDSL2 Network Card User Manual


 
1961221051L1-5, Issue 161221051L1-5A
Protection Configuration Screen
The protection configuration screens (Figure 21 and
22) provides status and control details for fault
protected circuits.
NOTE
The screens provided below are typical and
may vary slightly depending on the hardware
installed. For Instance, if HDSL2 H2TU-C
equipment is installed, certain screens will
change to indicate only 1 loop present.
11/23/99 00:32:51 PROTECTION CONFIGURATION SHELF ADDRESS = 00
[ SLOT 2 ]
________________________________________________
| PROTECTION OPTIONS CURRENT SETTINGS |
| ----------------------------------------- |
| 1. BER THRESHOLD = 1E-7 |
| 2. BER INTERVAL = 15 MINS |
| |
| |
| |
| |
| |
|________________________________________________|
MAIN CARD CAN ONLY SET THE BER OPTIONS.
-------------------------------- SHELF STATUS -------------------------------
| SLOT -> 01 02 03 04 05 06 07 08 09 10 11 12 13 |
| STATUS -> ^^---- ** ** ** ** ** ** ** ** ** |
|_____________________________________________________________________________|
^^—— = MAIN ACTIVE ——^^ = AUX ACTIVE ** = STANDARD HTU-C
Press: “nnS” - select slot, “nP” - select option,
“M” - main menu, “I” - implement and save current changes :
11/23/99 00:29:33 PROTECTION CONFIGURATION SHELF ADDRESS = 00
[ SLOT 3 ]
_____________________________________________________________________________
| PROTECTION OPTIONS CURRENT SETTINGS | SWITCHOVER HISTORY |
| ----------------------------------------- | ---------------------- |
| 1. PROTECTION MODE = AUTO | SWITCHOVERS -> 00 |
| 2. MINIMUM HOLDIN TIME = 01 MIN(S) | REVERSIONS -> 00 |
| 3. BER THRESHOLD = 1E-7 | FAILURES -> 00 |
| 4. BER INTERVAL = 15 MINS | LOCKOUTS -> 00 |
| 5. LOCKIN HOURS = 12 HR(S) | |
| 6. SWITCH TO AUX LIMIT = 09 (1-9) | |
| 7. LOCKIN CHECK INTERVAL = 20 MIN(S) | |
|________________________________________________|____________________________|
LOCKIN OPTIONS: IF 09 SWITCHOVERS OCCUR IN 20 MINUTES, LOCKIN FOR 12 HOURS.
SYSTEM CURRENT STATUS : NORMAL OPERATION
------------------------------------ SHELF STATUS ---------------------------
| SLOT -> 01 02 03 04 05 06 07 08 09 10 11 12 13 |
| STATUS -> ^^---- ** ** ** ** ** ** ** ** ** |
|_____________________________________________________________________________|
^^—— = MAIN ACTIVE ——^^ = AUX ACTIVE ** = STANDARD HTU-C
Press: “nnS” - select slot, “nP” - select option,
“M” - main menu, “I” - implement and save current changes :
Figure 22. Protection Screen (Aux)
Figure 21. Protection Screen (Main)