ADTRAN TSU 600 Network Card User Manual


 
Chapter 4. Example Operations
61200.076L2-1 TSU 600 User Manual 97
Figure 4-12
Window Showing the Error
To correct the setting press Enter twice to advance the
cursor to the Port data field. Use scrolling to display
the correct Port and Enter to record the selection.
The Temporary Map can be reviewed as many times
as necessary. When all corrections are completed use
Cancel to exit the Edit Temp menu. The unit returns
to the DS0 Map A submenu listing with the cursor on
6)APPLY TEMP >A. Press Enter to activate Apply.
Applying a map will not disrupt data flow.
The entire map can be cleared by first selecting CREATE,
which has all DS0s set to PSTRU=N and PORT=IDLE,
and then select APPLY to write the Idle map into the
Current map.
Use Cancel to exit DS0 Map A and return to the
Config submenu.