ADTRAN TSU 600 Network Card User Manual


 
Chapter 3. Operation
61200.076L2-1 TSU 600 User Manual 61
Unit
The Unit menu is used to change the baud rate of the
Control In port and the setup of the Dial Out port.
Operation
Follow standard operating procedure to access the
Unit menu.
With the cursor on 2)UNIT, activate the menu with
Enter or number 2. The unit displays the first two
submenu items.
Continue with standard operating procedure to select
the baud rate, set modem flow control, set up the
number used for alarm dial out, and exit the menu.
Unit Menu Items
The menu items are:
CTL PORT
Sets the baud rate for communication with the PC
or modem.
Options: 1200, 2400, and 9600 kbps.
TRAPS
Enables or disables the transmission of trap
messages.
ACCESS
Sets the method of connection from the TSU 100 to
T-Watch/SNMP.
Options:
- Direct - Used if connected directly to the PC.
- Dial - Used when connection is through a
modem.
The dial string is entered from T-Watch/SNMP.