Alcatel-Lucent 6800 Switch User Manual


 
Open Problem Reports and Feature Exceptions
page 78 OmniSwitch 6800/6850/9000—Release 6.1.3.R01
PR 107086
User with readwrite-scp-sftp privileges is initially queried for authentication and authorization on an
OS6850. After login to the scp/sftp shell, only accounting requests are sent to TACACS+ server (if
enabled), commands are not queried for authorization.
Workaround: There is no known workaround at this time.
PR 107278
SNMP variable policyStatsQueryCount always show as zero.
Workaround: See policyStatsAccessCount instead.
PR 107543
If Loopback0 is defined by the user and there is not a physical route for that IP subnet, a RADIUS client
will not be able to communicate with a RADIUS server. As a result, RADIUS authentication will fail as
the server is unreachable.
Workaround: There is no known workaround at this time.
General
Problem Reports
PR 86853
A stack of 9 or greater is not supported on an OS6800 or OS6850.
Workaround: The maximum stack elements is 8.
PR 93114
If an ingress packet is oversized, it is not for broadcast or multicast anymore. As a result, ingressing over-
sized layer 2 multicast packets are counted as unicast packets.
Workaround: There is no known workaround at this time.
PR 97213
On an OS9000, in all CPU exceptions, a Trace Buffer dump is offered at the beginning of the exception.
Workaround: There is no known workaround at this time.
System