Alcatel-Lucent 6800 Switch User Manual


 
Open Problem Reports and Feature Exceptions
page 82 OmniSwitch 6800/6850/9000—Release 6.1.3.R01
PR 104874
If CPU is at 100% on an OS6800, then the commands "copy working certified" or "copy working certified
flash-synchro" can make the system timeout and the primary will crash with pmd. The timeouts are printed
on the screen. So, the user can know when it timeouts. User has to be aware of the copy from working to
certified process.
Workaround: Prevent doing a copy working certified or copy working certified flash-synchro if high
CPU or remove CPU load.
PR 106941
Processing for CMM MIB variable chasTempRange not correct for non-primary slots on OS6800.
Workaround: There is no known workaround at this time.
PR 106975
If a WINTEK compact flash is installed on an OS6850, WINTEK is not displayed when you use the show
hardware info command.
Workaround: There is no known workaround at this time.
PR 107619
NI 1 becomes non-primary in a OS6850 stack after “reload stack” if NI 1 is an OS6850 Lite.
Workaround: There is no known workaround at this time.
Power Over Ethernet
Problem Reports
PR 99583
OS6850 POE units support either 510 or 360 Watt power supplies. If unlike power supplies are mixed, or
if an unsupported power supply, such as a 120-Watt power supply are used, a console message and a trap
are generated.
Workaround: There is no known workaround at this time.