Software Maintenance Version 281-02 includes the resolved issues and enhancements in the following tables. In the tables, for each product series:
“Y” in a white column indicates that the resolution is available in Version 281-02 for that product series.
“-” in a white column indicates that the issue did not apply to that product series.
a grey-shaded column indicates that Version 281-02 was not released on that product series.
Level 1
CR Module Level Description
AR400
AR7x5
AR750S / AR770S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948 / x900-48
AT-9900
AT-9800
CR00006040
PIM 6 1 For PIM on IPv6, if the interface that was being used as the BSR candidate address
went down, the network occasionally did not re-elect a BSR and the RPs in a
timely manner. This could cause the router or switch to reboot.
This issue has been resolved.
Y
-Y- --- - - -
CR00007273
Switch 1 If a user created a configuration file that contained port trunk settings before
VLAN port settings, then a loop occurred when the switch rebooted with this
configuration.
This issue has been resolved.
-
--- -Y- - - -
CR00013457
VLAN 1 When ports were added to a currently-disabled RSTP domain, the ports could
start to discard packets (because their STP state was set to Discarding).
This issue has been resolved. When ports are added to a disabled RSTP domain,
they remain in a Forwarding state.
- --- -Y- - - -
CR00013492
OSPF 1 When route filters (made with the command add ip route filter) were used to
filter OSPF routes, it was possible for OSPF to constantly remove and re-create an
AS-External LSA. This could prevent OSPF sessions from establishing.
This issue has been resolved.
Y