Allied Telesis AR44xS Switch User Manual


 
Features in 281-02 4
Version 281-02
C613-10482-00 REV B
Level 2
CR00013736
Core 1 When a BRI or PRI PIC was installed on the router, an issue with internal memory
handling occasionally caused the router to reboot.
This issue has been resolved.
Y
-Y- --- - - -
CR00013743
Switch 1 If a user created a configuration file that contained LACP settings and VLAN port
settings, then a loop occurred when the switch rebooted with this configuration.
This issue has been resolved.
-
--- -Y- - - -
CR Module Level Description
AR400
AR7x5
AR750S / AR770S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948 / x900-48
AT-9900
AT-9800
CR00010452
PIM 6 2 For PIM on IPv6, RPSet information did not expire correctly when all RP
candidates had expired.
This issue has been resolved.
Y
-Y- --- - - -
CR00010593
IPv6 2 The router or switch sometimes forwarded packets to directly connected hosts
whose corresponding IPv6 ND cache entry was still in INCOMPLETE state. This
caused it to send the packets to incorrect MAC addresses and egress ports.
This issue has been resolved.
Y
-Y- --- - - -
CR00012407
STAR 2 When the STAR protocol was used for link-layer encryption, the channel setup
failed continuously on heavy traffic.
This issue has been resolved.
Y
-Y- --- - - -
CR Module Level Description
AR400
AR7x5
AR750S / AR770S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948 / x900-48
AT-9900
AT-9800