Allied Telesis AT-S110 Switch User Manual


 
AT-GS950/10PS Switch Web Interface User’s Guide
255
2. From the RMON folder, select Alarm.
The RMON Alarm Configuration Page is displayed. See Figure 103.
Figure 103. RMON Alarm Configuration Page
3. The following fields are listed:
Index: This parameter specifies the ID number of the new group. The
range is 1 to 65535.
Interval: This parameter specifies the time (in seconds) over which the
data is sampled. Its range is 1 to 2147483647 seconds.
Variable: This parameter specifies the RMON MIB object that the
event is monitoring.
Sample type: This parameter defines the type of change that has to
occur to trigger the alarm on the monitored statistic. There are two
choices from the pull-down menu - DELTA value and ABSOLUTE
value. The DELTA setting compares a threshold against the difference
between the current and previous values of the statistic, while the
ABSOLUTE setting compares a threshold against the current value of
the statistic.
Rising Threshold: This parameter specifies a specific value or
threshold level of the monitored statistic. When the value of the
monitored statistic becomes greater than this threshold level, an alarm
event is triggered. The parameter’s range is 1 to 2147483647