Allied Telesis AT-S110 Switch User Manual


 
Chapter 28: Rebooting the AT-GS950/10PS
340
Configure Factory Default Values
The following procedure returns all AT-S110 Management software
parameters to their factory default values and deletes all tagged and port-
based VLANs on the switch.
Note
The AT-S110 Management software factory default values are listed
in “AT-GS950/8 Default Parameters” on page 347.
Caution
This procedure causes the switch to reboot. The switch does not
forward network traffic during the reboot process. Some network
traffic may be lost.
1. From the main menu on the left side of the page, select the Tools
folder.
The Tools folder expands.
2. From the Tools folder, select Reboot.
The Reboot Page is displayed. See Figure 133 on page 338.
3. Go to the lower part of the page to the Reboot section.
4. In the Reboot Type field, use the pull-down menu to select one of the
following options:
Normal - This setting reloads all configuration parameters that are
saved in flash memory. See “Switch Reboot” on page 338 for more
information when using this selection.
Factory Default - Resets all switch parameters to the factory
default settings, including the IP address, subnet mask, and
gateway address.
Caution
This setting will cause the IP address to be reset to 192.168.1.1.
You will loose connectivity with the switch management software
after the reboot is completed and you can login again with this IP
address.
Factory Default Except IP Address - Resets all switch parameters to
the factory default settings, but retains the current IP address, subnet
mask, and gateway settings saved in flash memory. If the DHCP client
is enabled, it remains enabled after this reset and assignment of the IP