When two devices are BSR candidates, and have the same preference set
with the SET PIM BSRCANDIDATE PREFERENCE command, the device
with the higher IP address was not elected as the candidate. This issue has
been resolved.
A Prune message sent to an old RP neighbour was ignored when a new
unicast route was learned. This issue has been resolved.
On Rapier series switches, an Assert message was not sent after the prune
limit expired. This issue has been resolved.
The log message “
IGMP Snooping is active, L3FILT is activated
has been changed to “
IGMP packet trapping is active, L3FILT is
activated
”. The revised message is clearer when IGMP is enabled and
IGMP snooping is disabled.
The following changes have been made to the ADD FIREWALL POLICY
RULE and SET FIREWALL POLICY RULE commands:
An IP address range for the IP parameter is now only accepted when
enhanced NAT is configured.
An IP address range for GBLREMOTE parameter is now only accepted
when reverse or reverse-enhanced NAT is configured.
The GBLIP parameter is not accepted for a public interface when
enhanced NAT is configured.
Port link status LEDs on disabled ports were not always operating correctly
on AT-8800 Series switches. This issue has been resolved.
Table 4: New parameters displayed in the output of the SHOW SYSTEM command
for AT-8800 series switches.
Parameter Meaning
Current Temperature The status of the switch’s temperature. “Normal” means
the switch is operating in the required temperature range.
“Warning” means there has been a temperature-related
error requiring attention. “Failed” means there was an
internal error while reading the temperature.
Fan Status The status of each of the switch’s four fans. “Normal”
means the fan is operating as expected. “Warning” means
a fan is operating outside the desired range. “Failed”
means there was an internal error while reading the fan
status.
PCR: 31040 Module: PIM Level: 2
PCR: 31041 Module: PIM Level: 3
PCR: 31042 Module: PIM Level: 3
PCR: 31044 Module: SWI Level: 4
PCR: 31052 Module: FIREWALL Level: 3
PCR: 31057 Module: SW56 Level: 4