Allied Telesis SB251-13 Switch User Manual


 
Patch SB251-13 For SwitchBlade 4000 Series Switches and AT-9800 Series Switches 21
Patch SB251-13 for Software Release 2.5.1
C613-10361-00 REV M
connections will now only retry SYNs once after 5 seconds. The round robin
selection algorithm will now select an UP resource in a resource pool with
only one UP resource, even if it was used for the last successful connection.
Sometimes healthcheck pings were not sent to the load balancer resources.
This issue has been resolved.
The system became unstable if the ADD IPV6 TUNNEL command failed.
This instability was caused by the partially created tunnel entry not being
properly removed from the tunnel database. The tunnel entry is now
completely removed.
Invalid routes and packets were occurring within RIP. This issue has been
resolved.
AT-9800 Series switches with 16 ports could be configured beyond their 16
port maximum. Attempting to configure port 17 would produce no error
message, and attempting to configure ports 18 and above would result in an
incorrect error message. Also, the SwitchBlade could be allocated with 17
ports within a single trunk group, one port more than the maximum. These
issues have been resolved; in both instances the maximum port
configuration is now 16.
RIPng was not sending a response back to a RIP request message. This issue
has been resolved.
IPv4 filters now behave like IPv6 filters.
The SHOW SYSTEM SYSR SLAVE COUNT and SHO SYS SYSR SLAVE
commands have been removed from the user command set.
When the configuration script was created using the CREATE CONFIG
command, the GBLIP parameter in the ADD FIREWALL POLICY
command was listed twice. This caused the command to fail when the
device was restarted. This issue has been resolved.
PCR: 03194 Module: LB Level: 3
PCR: 03196 Module: IPV6 Level: 3
PCR: 03199 Module: IPV6 Level:
PCR: 03201 Module: SWI Level: 4
PCR: 03203 Module: IPV6 Level: 3
PCR: 03206 Module: IPG Level: 3
PCR: 03207 Module: Alarm Level: 4
PCR: 03208 Module: FIREWALL Level: 2