Allied Telesis SB251-13 Switch User Manual


 
Patch SB251-13 For SwitchBlade 4000 Series Switches and AT-9800 Series Switches 37
Patch SB251-13 for Software Release 2.5.1
C613-10361-00 REV M
On SwitchBlade and AT-9800 Series switches, adding a static ARP entry
resulted in the entry of the MAC address being added for the next hop port.
These addresses were being incorrectly added if the next hop port was
configured as a tagged port. This issue has been resolved.
The timing of LLQ packets has been modified to be consistent with MLD
Draft (Nov 2002).
BGP/IPG was causing fatal errors to occur following network topology
changes. This issue has been resolved.
Setting addresses using the SET SWITCH BLADE IP command resulted in
the SHOW SWITCH TAB=IP command displaying incorrect addresses.
RIP packets can now contain up to 25 routes per packet instead of 24.
When a radius lookup performed by the L2TP Access Concentrator (LAC)
failed, the LAC attempted to disconnect the call from its tunnel. If the tunnel
had not been created, the device restarted. This issue has been resolved.
PINGING between blades within the same switch failed whenever the
current master was located in the right-hand slot and a control blade was
located in the left-hand slot. This issue has been resolved.
A PAP authentication failure with PPPoE could cause a fatal error. This
issue has been resolved.
The MAXSESSION parameter of the SET PPP ACSERVICE command could
not be changed when the service was defined over a VLAN. This issue has
been resolved.
The port formatting for alarm messages was incorrect. This issue has been
resolved.
Static IP ARP entries were not being written to the hardware table. This
issue has been resolved.
PCR: 03275 Module: SWI Level: 2
PCR: 03278 Module: IPV6 Level: 4
PCR: 03280 Module: IPG, BGP Level: 1
PCR: 03284 Module: SWI Level: 4
PCR: 03285 Module: IPG Level: 4
PCR: 03288 Module: L2TP Level: 2
PCR: 03290 Module: SWI Level: 2
PCR: 03291 Module: PPP Level: 2
PCR: 03293 Module: PPP Level: 3
PCR: 03294 Module: Alarm Level: 4
PCR: 03295 Module: IP Level: 2