Altinex 400-0026-004 Switch User Manual


 
MATRIX SWITCHERS
14
command. The [UIDnE] command should be
used to disable all levels and enable only the
unit that needs to be controlled. This command
can not be used with unit ID 0 or 1.
For example, at power up, all units can be
controlled. To control level 3 only, issue the
command - [UID3E].
[IkkOmm]
kk = input number 01 to 16
mm = output number 01 to 16
This command connects the specified input to
outputs and switches them immediately.
For example, if you want to connect input 2 to
output 11 and switch, type [I02O11]. If input
number 00 is used, that input is disconnected
from the selected output. The connection stays
active until those particular inputs or outputs
are disabled or the unit is reset.
[IkkOmmP]
xx = input number 01 to 16
mm = output number 01 to 16
P = path
This command loads input to output
connections, but does not switch. Through this
command input to output connections are
loaded (path is set), but not switched until a
[SW] command or a direct connection
command of [IxxOmm] is sent. This command
is used to select multiple inputs and multiple
outputs without switching. This is a very useful
command for scene or salvo switching. If input
number 00 is used that input is disconnected
from the selected output
For example, If you want to connect input 2 to
output 11 and do not switch, type [I02O11P]
[IkkOmmUn]
kk = Input number 01 to 16
mm = Output number 01 to 16
n = Unit ID# (n=2 to 9)
This command allows any input to be
connected individually to any output within the
HOMERUN module with a specific Unit ID. For
example, in a RGBHV + Mono Audio
combination where RGB = Unit ID2, HV = Unit
ID3, and Mono Audio = Unit ID4, the
[I12O10U2] command will connect input 12 to
output 10 on RGB units and not on HV or audio
modules. [I03O10U4] will connect input 3 to
output 10 on audio modules and not on
RGBHV units.
If n = 1, units will respond to any command. If
n= 0, then none of the units will respond to any
issued command.
[IkkOmmUnP]
kk = Input number 01 to 16
mm = Output number 01 to 16
n = unit ID# (n=2 to 9)
P = path
This command allows any input to be
connected to any output on a particular
module, but not switched. For example, in an
RGBHV + Mono Audio combination where
RGB = Unit ID2, HV = Unit ID3, and Mono
Audio = Unit ID4, by putting n=3, one can
easily load H&V signals only for switching or by
using n=4 one can easily load only audio for
switching. No switching take places until any of
the switch [SW] or [IxxOmm] or [IxxOmmUn]
commands are received. This command is very
helpful in large matrix systems or when using
PC based software.
If n = 1, units will respond to any command and
if n= 0, then none of the units will respond to
any issued command.
[IkkOXX]
kk = specific input to be controlled
01-16
This command selects the input to control.
Once the input number to be controlled is set
by this command, that input can be connected
to multiple outputs through the connect
command, [IXXOmmC].
[IXXOmm]
mm = output number 00 to 16