Altinex MT105-101 Switch User Manual


 
MULTI-TASKER
400-0131-004
13
13
12. […P] – PATH
This command will set the path for the output,
but it is not active until the switch command,
[SW], is executed. Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card can be
preloaded. See the examples in [ON] and [OFF]
commands.
Example:
There is an MT105-100 in slot 4. Currently,
Input 1 is connected to all outputs and all
outputs are on. The path command has been
used to set Input 2 to Output 1 and turn off
Outputs 2 and 3 at the same time. If checking
the status prior to sending the [SW] command,
the feedback will appear as follows for the
above connection settings:
In01-Out1 ON P=2
In01-Out2 ON P=OFF
In01-Out3 ON P=OFF
In01-Out4 ON
In01-Out5 ON
In01-Out6 ON
In01-Out7 ON
The notation "P=" at the end of the line indicates
the path condition is active. "P=2" on the
Output 1 line indicates that after the [SW]
command, Input 2 will be connected to
Output 1.
The notation "P=OFF" on lines 2 and 3 indicates
that Outputs 2 and 3 will be turned off after the
[SW] command is executed.
13. [SW] SWITCH
This command immediately connects inputs and
outputs previously set with the path command.
The command switches all paths set on this
card and all other cards in the enclosure.
Example:
The following commands set the path for turning
on Output 1 of the card in slot 6 and turning off
Output 3 of the card in slot 9. Nothing happens
until the [SW] command is sent. At that time,
Output 1 will be enabled and Output 3 will be
disabled.
[ON1C6P] , [OFF3C9P] and [SW]
14. [ImOx]
This command connects a single input to a
single output in the current matrix configuration.
Command Format: [ImOxCnUi]
m = Input (m= # from 1 to 16)
x = Output (x = # from 1 to 8)
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Connect Input 1 to Output 1 for the MT105-100
in slot 5. Send the command [I1O1C5] and
Input 1 will be connected to Output 1.
15. [ImO*]
This command connects a single input to all the
outputs in the current matrix configuration.
Command Format: [ImO*CnUi]
m = Input (m = # from 1 to 16)
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Connect Input 1 to all outputs for the
MT105-100 in slot 5. Send the command
[I1O*C5] and Input 1 will be connected to all
outputs.
16. [CLR]
This command performs a reset of the card and
restores settings to the factory defaults.
Command Format: [CLRCnUi]
Cn = Card ID (n = # from 1 to max slots)