Alvarion BU-DS.11 Network Router User Manual


 
BreezeNET DS.11 Series User Manual
3-26
Send Trap Interval (sec): The time interval between two successive traps
when the number of transmitted broadcasts/multicasts exceeds the
permitted threshold.
The range is from 0 to 65535 seconds. 0 is for disabling traps sending.
The default is 300 seconds.
Auto-Config Tab
The Auto-Config tab enables quick configuration of various modes by setting
predefined values for several parameters upon clicking the applicable button.
Figure
3-16: Auto-Config Tab
Set PtP Mode: Click to set the following parameters to support optimized
configuration for Point-to-Point operation:
Minimum Contention Window = 15
RTS Threshold = 2437
Set PtMP Mode: Click to set the following parameters to support optimized
configuration for Point-to-Multi-Point operation with 2-5 RBs:
Minimum Contention Window = 63