Alvarion BU-DS.11 Network Router User Manual


 
Technical Specifications
6-3
Outdoor Unit-to-Indoor Unit Communication
Cable Type
Cat 5 FTP 4x2x24 Double Jacket
Maximum Cable length
100 m (including the length of the Ethernet cable to the user equipment)
Interfaces
RF (antenna) connector in
the outdoor unit (DS.11D
models)
N-Type jack, lightning protected
Outdoor units: Shielded RJ-45 with special water proof sealed cap
Baseband
(indoor-to-outdoor units)
Indoor units: Shielded RJ-45
Ethernet
Indoor units: 10BaseT, (RJ-45) with 2 embedded LEDs
Electrical
Power Consumption
110VAC: 25W
220VAC: 24W
Mechanical Dimensions
Outdoor Unit
30.5 x 12 x 5 cm (12 x 4.7 x 2 inch)
Indoor Unit
16 x 9 x 6 cm (6.3 x 3.5 x 2.3 inch)
Environmental
Operating Temperature
Indoor unit: 0°C to 40°C (32°F to 104°F)
Outdoor unit: -40°C to 55°C (-40°F to 131°F)
Operating Humidity
5% to 95% non-condensing. Outdoor units are weather protected.
Standards Compliance, General
EMC
EN 300-385, FCC Part 15
Safety
EN 60950, UL 1950
Environmental
ETS 300 019
Radio
ETSI ETS 300 328, FCC Part 15