13
1. REVERSING SETUP – The parameters that pertain to the Reversing Mode are in this menu level.
0. ENTER SPIN TIME 30 TO 120 SECONDS – This parameter (program) is fixed at 2 minutes in the
forward direction and 2 minutes in the reverse direction for the Automatic Mode. In the Manual Mode,
it is programmable. This Spin Time is programmed here for the Manually Loaded Manual Cycle only.
1. ENTER STOP TIME 5 TO 10 SECONDS – This parameter (program) is fixed at 5-seconds in the
Automatic Mode and programmable in the Manual Mode. This Dwell (Stop) Time is programmed here
for the Manually Loaded Manual Cycle only.
2. WRINKLE GUARD SETUP – The parameters that pertain to the Wrinkle Guard are in this menu level.
0. WRINKLE GUARD AUDIO ALERT – This parameter (program) allows the operator to turn the
Audio Alert tone on or off at the end of each Wrinkle Guard Cycle.
AUDIO ALERT ON
AUDIO ALERT OFF
3. STEAM INJECTION SETUP (Optional) – This parameter is used to inject steam into the basket
(tumbler) up to 5 times. 0-5 ON Time is first entered MM:SS (minutes:seconds), and then the OFF
Time is entered MM:SS (minutes:seconds).
2. PROGRAM A-F CYCLES – This menu allows the programming of cycles “A-F”. The parameters
selected in this menu for each letter
will be stored in memory for that key. This will allow the operator to
utilize one-touch drying through keys “A-F”.
3. PROGRAM 0-40 CYCLES – This menu allows the programming of cycles “0-40”. The parameters
selected in this menu for each number will be stored in memory for that number key(s). This will allow the
operator to utilize preprogrammed drying cycles stored in memory under a numerical location.
NOTE: BOTH THE “A-F” and “0-40” CYCLES ALLOW FOR A TOTAL OF 47
PREPROGRAMMED LOCATIONS FOR CUSTOM DRYING.
4. DEFAULT SETTINGS – This menu allows the operator to set ALL programmable parameters to default
settings. This option has a password selection of 1 2 3. It will then ask to confirm settings. It will default
to “NO”. Use the arrow keys to select “YES”.
CAUTION: Once the settings have been set to their default settings, there is no way to
retrieve the old settings. Use caution when using this feature.