American Dryer Corp. Phase 7.2.2 Network Card User Manual


 
27
0: SELECT LANGUAGE
ENGLISH
FRANCAIS
ESPANOL
ITALIANO
DEUTSCH
1: SELECT SYSTEM PARAMETERS
0: DRYER SETUP
0: SELECT MODEL
GAS REVERSING
ELECTRIC REVERSING
STEAM REVERSING
GAS NON-REVERSING
ELECTRIC NON-REVERSING
STEAM NON-REVERSING
1: SYSTEM TEMP
DEG F
DEG C
2: ENTER LINT CLEANING FREQUENCY 1 TO 10 HOURS
3 (3 = DEFAULT VALUE)
3: ENTER AUDIO ALERT ON TIMES 0 TO 10
5 (5 = DEFAULT VALUE)
4: ENTER ROTATION SENSOR ON/OFF (ON = DEFAULT VALUE)
5: BOARD ADDRESS 00 TO ZZ.
6: AUTO CYCLE TIME OUT 0 TO 99 MINUTES 60 (60 = DEFAULT VALUE)
1: REVERSING SETUP
0: ENTER SPIN TIME 30 TO 120 SECONDS
60 SEC (60 = DEFAULT VALUE)
1: ENTER STOP TIME 5 TO 10 SECONDS
5 SEC (5 = DEFAULT VALUE)
2: WRINKLE GUARD SETUP
0: WRINKLE GUARD AUDIO ALERT
AUDIO ALERT ON
AUDIO ALERT OFF
3: STEAM INJECTION SETUP
0: ENTER ON TIME
10:00 = DEFAULT
1: ENTER OFF TIME
(1-SECOND ABOVE ON TIME – DEFAULT)