75
SECTION VII
FACTORY PRESET PARAMETERS (PROGRAMS)
NOTE: To enter Program Mode, press and hold the “STOP/CLEAR” key and the “UP ARROW”
key.
A. CYCLE “A-F” PARAMETERS (PROGRAMS) PRESET BY THE FACTORY
CYCLE A:
SELECT CYCLE TYPE = AUTO, 0:REVERSE MODE = ON, 1:ENTER DRY TEMP = 180°F, 2:ENTER DRYNESS LEVEL =
EXTRA DRY, 3:ENTER CYCLE ADJUSTMENT VALUE = 70, 4:CONTROLLED COOL DOWN = OFF, 5:ENTER COOL DOWN
TIME = 6 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F
CYCLE B:
SELECT CYCLE TYPE = AUTO, 0:REVERSE MODE = ON, 1:ENTER DRY TEMP = 180°F, 2:ENTER DRYNESS LEVEL = DRY,
3:ENTER CYCLE ADJUSTMENT VALUE = 70, 4:CONTROLLED COOL DOWN = OFF, 5:ENTER COOL DOWN TIME = 6
MINUTES, 5:ENTER COOL DOWN TEMP = 80°F
CYCLE C:
SELECT CYCLE TYPE = AUTO, 0:REVERSE MODE = ON, 1:ENTER DRY TEMP = 160°F, 2:ENTER DRYNESS LEVEL = DRY,
3:ENTER CYCLE ADJUSTMENT VALUE = 70, 4:CONTROLLED COOL DOWN = OFF, 5:ENTER COOL DOWN TIME = 4
MINUTES, 5:ENTER COOL DOWN TEMP = 80°F
CYCLE D:
SELECT CYCLE TYPE = MANUAL, 0:REVERSE MODE = ON, ENTER SPIN TIME = 60 SECONDS, ENTER STOP TIME = 5
SECONDS, 1:ENTER DRY TIME = 40 MINUTES, 2:ENTER DRY TEMP = 190°F, 3:CONTROLLED COOL DOWN = OFF,
4:ENTER COOL DOWN TIME = 6 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F, 6:STEAM INJECTION = OFF
CYCLE E:
SELECT CYCLE TYPE = MANUAL, 0:REVERSE MODE = ON, ENTER SPIN TIME = 60 SECONDS, ENTER STOP TIME = 5
SECONDS, 1:ENTER DRY TIME = 30 MINUTES, 2:ENTER DRY TEMP = 180°F, 3:CONTROLLED COOL DOWN = OFF,
4:ENTER COOL DOWN TIME = 4 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F, 6:STEAM INJECTION = OFF
CYCLE F:
SELECT CYCLE TYPE = MANUAL, 0:REVERSE MODE = ON, ENTER SPIN TIME = 60 SECONDS, ENTER STOP TIME = 5
SECONDS, 1:ENTER DRY TIME = 10 MINUTES, 2:ENTER DRY TEMP = 170°F, 3:CONTROLLED COOL DOWN = OFF,
4:ENTER COOL DOWN TIME = 2 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F, 6:STEAM INJECTION = OFF
B. CYCLE “0-40” PARAMETERS (PROGRAMS) PRESET BY THE FACTORY
CYCLE “0-40”:
Manual (Timed) Mode, Reverse, Dry Time = 0, Dry Temp = 100, Cool Down Time = 3 Minutes, Cool Down
Temp = 100, Spin Time = 60, Dwell (Stop) Time = 7.