Anritsu S332D Network Router User Manual


 
Set Spectrum Analyzer Marker to Peak – Control Byte #109 (6Dh) ....................86
Set Spectrum Analyzer Marker to Center – Control Byte #110 (6Eh) ...................86
Set Spectrum Analyzer Attenuation – Control Byte #111 (6Fh) ......................87
Set Site Master VNA Segmented Limit Lines – Control Byte #112 (70h) .................87
Set Spectrum Analyzer Multiple Limit – Control Byte #113 (71h) ....................88
Set Return Spectrum Analyzer Sweep Time – Control Byte #114 (72h) ..................89
Set Reference Level Offset – Control Byte #115 (73h) ...........................89
Read Marker Value – Control Byte #117 (75h) ...............................90
Set Sweep Averaging – Control Byte #118 (76h) ..............................90
Field InstaCal – Control Byte #120 (78h) ..................................90
Read InstaCal Module ASCII Serial Number – Control Byte #124 (7Ch) .................91
Set Site Master Marker (Peak/Valley) – Control Byte #129 (81h) .....................91
Set / Reset Spectrum Analyzer External Reference – Control Byte #133 (85h) ..............91
Check Spectrum Analyzer External Reference – Control Byte #134 (86h).................92
Set SPA Preamp State (On/Off/Auto) – Control Byte #136 (88h) .....................92
Set Spectrum Analyzer Units – Control Byte #140 (8Ch) .........................92
Set Spectrum Analyzer Resolution Bandwidth – Control Byte #141 (8Dh) ................93
Set Spectrum Analyzer Video Bandwidth – Control Byte #142 (8Eh) ...................93
Set Spectrum Analyzer Attenuation – Control Byte #143 (8Fh) ......................93
Set AM/FM Demodulation – Control Byte #145 (91h) ...........................94
Set Baud Rate – Control Byte #197 (C5h) .................................95
Set Language – Control Byte #198 (C6h) ..................................95
Query Time – Control Byte #208 (D0h) ..................................95
Read ASCII Serial Number – Control Byte #225 (E1h) ..........................96
Exit Remote Mode – Control Byte #255 (FFh) ...............................96
Set T1 Transmission Level – Control Word (A001h) (Option 50 only) ..................96
Set T1/E1 Clock Source – Control Word (A002h) (Option 50 only) ....................96
Set T1/E1 Pattern – Control Word (A003h) (Option 50 only) .......................97
Set T1/E1 Error Insert Type/Value – Control Word (A004h) (Option 50 only) ..............97
Set T1/E1 Framing Mode – Control Word (A005h) (Option 50 only) ...................98
Start and Stop T1/E1 Measurement – Control Word (A006h) (Option 50 only) ..............98
Insert Error for T1/E1 Measurement – Control Word (A007h) (Option 50 only)..............98
Get T1/E1 Pattern – Control Word (A008h) (Option 50 only) .......................98
Get T1/E1 Frame Sync Status – Control Word (A009h) (Option 50 only) .................99
Get T1/E1 Pattern Sync Status – Control Word (A00Ah) (Option 50 only) ................99
Get T1/E1 Carrier Status – Control Word (A00Bh) (Option 50 only) ...................99
Get T1/E1 Error Type and Number – Control Word (A00Ch) (Option 50 only) ..............99
Set T1/E1 Line Coding Options – Control Word (A00Dh) (Option 50 only) ...............100
Set E1 Impedance Options – Control Word (A00Eh) (Option 50 only) ..................100
Read T1/E1 Volts Peak-to-Peak – Control Word (A00Fh) (Option 50 only) ...............100
Site Master PM iii