189) Cable Loss
190) Cable Loss (lowest byte)
191) Average Cable Loss
155
(highest byte)
192) Average Cable Loss
193) Average Cable Loss
194) Average Cable Loss (lowest byte)
195) Status Byte 1: ( 0b = Off , 1b = On)
(LSB) bit 0 : Marker 1 On/Off
bit 1 : Marker 2 On/Off
bit 2 : Marker 3 On/Off
bit 3 : Marker 4 On/Off
bit 4 : Marker 5 On/Off
bit 5 : Marker 6 On/Off
bits 6-7 : Not Used
196) Status Byte 2: (0b = Off, 1b = On)
(LSB) bit 0 : Marker 2 Delta On/Off
bit 1 : Marker 3 Delta On/Off
bit 2 : Marker 4 Delta On/Off
bits 3-7 : Not Used
197) Status Byte 3: ( 0b = Off , 1b = On)
(LSB) bit 0 : Single Limit On/Off
bit 1: CW On/Off
bit 2: Trace Math On/Off
bits 3-5 : Not Used
bit 6 : Limit Type ( 0b = Single; 1b = Multiple)
bit 7 : Unit of Measurement (1b = Metric, 0b = English)
198) Status Byte 4:
(LSB) bit0-1:DTFWindowing Mode
bit: 1 0
||
0 0 - Rectangular (No Windowing)
0 1 - Nominal Side Lobe
1 0 - Low Side Lobe
1 1 - Minimum Side Lobe
bits2–7:NotUsed
199) Status Byte 5 (Cal Status):
00h : Calibration Off
01h : Standard Calibration On
02h : InstaCal Calibration On
03h : Standard FlexCal On
04h : InstaCal FlexCal On
200) VNA Signal Standard
156
(higher byte)
201) VNA Signal Standard (lower byte)
202-324) Not Used
325-1364)Sweep Data (130 points * 8 bytes/point = 1040 bytes)
325-2396)Sweep Data (259 points * 8 bytes/point = 2072 bytes)
325-4460)Sweep Data (517 points * 8 bytes/point = 4136 bytes)
8 bytes for each data point
1. gamma
157
(highest byte)
52 Site Master PM
155 Average Cable Loss is dB * 1000.
156 Index into Standard List (use control byte #89 to retrieve the ASCII string name). “No Standard” sent as FFFEh
157 Gamma data uses 1/10,000 units.