APC H10 Power Supply User Manual


 
- 5 -
Switched On Status Indicator
If illuminated, power is on at all outlets except those with a pro-
grammed delay.
Delayed On Status Indicator
If illuminated, power is ‘on’ at those outlets.
Line Trim Status Indicator
Automatic Voltage Regulation (AVR) is engaged to correct high
input voltage conditions.
SEQ/AVR Push Button
This push button is used to adjust the AVR range of the H10, as
well as to set the Delay time for sequenced outlets. To adjust
H10 AVR range, or to set the Delay time, proceed as follows:
To set the AVR range:
1. Push and hold the SEQ/AVR push button for three seconds;
all LEDs are extinguished, indicating the H10 is in delay
programming mode. The LED corresponding to the current
AVR range setting flashes (Narrow, Normal, or Wide).
2. To change AVR range, press the SEQ/AVR push button
until the LED corresponding to the desired setting flashes.
After releasing the push button, the unit returns to normal
status and the normally illuminated LEDs are lit.
The AVR Range adjustments have the following value:
Narrow AVR Range: 102-132 Volts,
Regulates to: 120 Volts + 5%
Normal AVR Range: 97-139 Volts,
Regulates to: 120 Volts + 10%
Wide AVR Range: 92-145 Volts,
Regulates to: 120 Volts + 15%
5
6
7
8