ATEN Technology CS-9134 Switch User Manual


 
Operation
Hot Plugging
The Master View CS-9134 / CS-9138 supports hot plugging. Components can
be removed and added back into the installation by unplugging and replugging
their cables from their respective ports without the need to shut the switch
down. For hot plugging to work properly, the following procedures must be
observed:
u
Hot Plugging CPU Ports:
When hot plugging cables from the CPU ports:
1. The cable must be plugged back into the same port it was removed
from.
2. The mouse cable must be plugged in before the keyboard cable.
3.
After plugging the cable back in, you must perform a KVM Reset on the
First Stage unit (by pressing the Reset switch In).
u
Hot Plugging Console Ports:
The unit supports hot plugging of the keyboard, monitor, and mouse. When
hot plugging the mouse from the console mouse port:
1. You may unplug the mouse and plug it back in again (to reset the
mouse, for example), as long as you use the same mouse.
2. If you plug in a different mouse, all the stations and all the computers on
the installation must be shut down for 10 seconds, then restarted. (Refer
back to the note describing the Power On sequence on p. 10, if
necessary.)
Note: If, after hot plugging (or at any other time), there is no response to
mouse and/or PS/2 keyboard input, simultaneously press and hold
Port Select buttons 1 and 2 on the First Stage unit for 3 seconds to
perform a PS/2 Keyboard and PS/2 Mouse reset.
2005-12-21
CS-9134 / CS-9138 User Manual 11