Atmel ATA6264 Power Supply User Manual


 
69
4929B–AUTO–01/07
ATA6264 [Preliminary]
21.7
Time from SSQ falling edge to
MISO MSB valid
(2)
MISO t
MISOMSB_V
0 400 ns A
21.8
Time from SCLK rising edge to
MISO valid
(2)
MISO t
MISOV
040nsA
21.9
Time from SSQ rising edge to
MISO tristate condition
(2)
MISO t
MISOhiZ
040nsA
21.10
No-data time between serial
interface commands
t
nodata
1.5 µs A
(3)
21.11 Clock frequency CLK f
SCLK
08MHzA
(3)
21.12 Pull-up current VPERI SSQ R
pu_SSQ
–95 –45 µA A
21.13 Pull-up current VPERI SCLK R
pu_SCLK
–95 –45 µA A
21.14 SCLK high/low time SCLK t
CL
40 ns A
(3)
21.15 Input voltage high level
SSQ, SCLK,
MOSI
V
H
0.5 ×
V
VPERI
A
21.16 Input voltage low level
SSQ, SCLK,
MOSI
V
L
0.25 ×
V
VPERI
A
21.17 Input voltage hysteresis SCLK V
HYS
50 250 mV A
21.18 Output voltage high level I
MISO
= –1 mA to 0 mA MISO V
H
V
VPERI
– 0.8
V
VPERI
VA
21.19 Output voltage low level I
MISO
= 0 mA to 1 mA MISO V
L
00.4VA
21.20
Output current high level driven
to short circuit
V
VPERI
= 5V MISO I
MISO
–47 –10 mA A
21.21
Output current low level sinking
from VPERI level
V
VPERI
= 5V MISO I
MISO
645mAA
21.22 Input capacitance
SSQ, SCLK,
MOSI
C
IN
10 pF D
21.23 Output capacitance Switched-off condition MISO C
MISO
10 pF D
21.24 Leakage current Switched-off condition MISO I
MISO
–10 +10 µA A
21.25
Number of clock cycles to be
detected between falling and
rising edge of SSQ, to set error
signal in status register to “0”
16 16 A
Table 22-1. Electrical Characteristics (Continued)– Serial Interface Commands
No. Parameters Test Conditions Pin Symbol Min Typ. Max. Unit Type*
*) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter
Note: 1. Voltage levels for serial interface timing measurements: High level = 0.7 × V
VPERI
, low level = 0.2 × V
VPERI
2. Timing specified with a 100-pF external load at pin MISO
3. System requirement