Avocent CPS1610 Switch User Manual


 
Chapter 5: CPS Appliance Commands 69
SPC Command
The SPC command changes settings for an SPC device and its sockets.
NOTE: This command configures the port for use with the DSView software. For standalone use of the SPC
device, this command should not be used, and the CPS port to which the SPC is attached should be configured
as TD=Console.
Access right: SCON or PCON
Access level: ADMIN or APPLIANCEADMIN
Syntax
SPC <port>|ALL [MINLOAD=<amps>] [MAXLOAD=<amps>] [SOCKET <socket>|ALL]
[WAKE=ON|OFF] [ONMIN=<time>] [OFFmin=<time>]
Level
User’s access level. If a level was not configured, access rights determine the level:
Users with SCON access => APPLIANCEADMIN.
Users with USER or PCON but not SCON => ADMIN.
Otherwise, USER level is assigned.
Access User’s access rights and preemption level.
Table 5.34: Show User All Command Display Fields (Continued)
Field Contents
Table 5.35: SPC Command Parameters
Parameter Description
<port> Port number in range 1-8 for a CPS810 appliance or 1-16 for a CPS1610 appliance.
ALL
Indicates that the settings that follow should be applied to all ports configured
as SPC.
MINLOAD=<amps>
Minimum load in amperes in the range 0-30. A 0 value indicates no minimum load.
Default = 0
MAXLOAD=<amps>
Maximum load in amperes in the range 0-30. A 0 value indicates no maximum load.
Default = 0
SOCKET <socket>|ALL
Either a socket number on the SPC or All, which indicates that the settings that
follow should be applied to all sockets on the SPC.
WAKE=ON|OFF
State that the socket will enter when the SPC is powered up.
Default = ON