Axis Communications AXIS Q7406 Network Card User Manual


 
35
AXIS Q7406 - Resetting to the Factory Default Settings
Resetting to the Factory Default Settings
This will reset all the parameters, in all 6 units (including all six IP addresses), to the
factory default
settings.
1. Press both the Reset button and Control button.
2. Release the Reset button and hold the Control button.
3. Keep the Control button pressed until the Power indicator turns green and the six
Status indicators turn amber (this may take up to 15 seconds).
4. Release the Control button. When the Status indicators display green (which can take
up to 1 minute) the process is complete and the video encoder has been reset.
5. Re-assign the IP addresses, using one of the methods described in this document.
To reset an individual unit to the original factory default settings, use the button
provided in that unit’s web interface. For more information, please see the online help.
Note: For other methods of setting the IP address, please refer to the product’s Installa-
tion Guide that accompanies the product, or download a copy from
www.axis.com