STATUS User Guide
12 MGP D5
STATUS
PERMANENT GREEN LIGHT
The projector is turned on and in normal operation.
PERMANENT YELLOW LIGHT
The unit is in standby mode; no source(s) connected, or the
source(s) connected are inactive or switched off, thereby
activating the power-save function (DPMS). You may enable or
disable the power save function in the SET UP sub menu, DPMS
on or off.
FLASHING YELLOW LIGHT
Please wait. The yellow light will flash a period after power cord
is connected (10-15 sec.), and a period after going to standby
mode while lamp is cooling down (approximately 45 sec.). The
projector may not be turned on again until the light has turned to
permanent yellow.
PERMANENT RED LIGHT
Lamp life has expired. Please change projection lamp
immediately. Failing to change lamp may lead to lamp explosion.
FLASHING RED LIGHT
Projector is overheated. Turn off immediately! Check if air inlets
are covered or if ambient temperature is outside specifications.
The projector can not be restarted unless the power cord is
disconnected and reconnected again. If the projector continues to
flash red, you will need to return the unit for service.
STATUS
POWER